Sensor Type
Electrochemical
Measuring Ranges
Ammonia(NH3)
Carbon Monoxide (CO)
Chlorine (CL2)
Chlorine Dioxide (CLO2)
Ethylene (C2H4)
Ethylene Oxide (C2H4O)
Hydrogen Chloride (HCL)
Hydrogen Sulfide (H2S)
Hydrogen (H2)
Hydrogen Cyanide (HCN)
Methyl Mercaptan (CH3SH)
Nitrogen Dioxide (NO2)
Nitric Oxide (NO)
Oxygen Deficiency (O2)
Sulfur Dioxide (SO2) |
0-50 ppm
0-100, 0-1000 ppm
0-10 ppm
0-50 ppm
0-100 pm
0-50 ppm
0-20 ppm
0-100 ppm
0-100, 0-1000 ppm
0-30 ppm
0-100 ppm
0-20 ppm
0-100ppm
0-25% by volume
0-50 ppm
|
|
Repeatability
± 2 % Full scale
Zero Drift
< 5% per year
Typical Response Time
T90 < 30 seconds with 100% FS
gas applied
Classification
Class I, division 1, Groups B,C &
D
Operating Temperature
-4°F to +122°F (-20°C
to +50°C)
Operating Humidity
15% to 90% RH, non-condensing
Display
Bright 3 digit LED display
|
Status Indicators
Three-digit display for gas concentration, Alarm relay status, calibration mode and sensor fault status.
Mechanical Specifications
Length: 7 inches (178 mm) Width: 5 inches (127 mm) Height: 4.5 inches (114 mm)
Input Power
14-28 VDC. 24 VDC nominal
Power Consumption
50mA @ 24 VDC typical
Alarm Relays
Fully programmable. 0 to Full scale range of the sensor. Latching or Non-Latching.
Relay Ratings
SPDT Form "C" type Relay contacts 5 Amps @ 250 VAC or 30 VDC
Analog Output
Linear 4-20mA (300 Ohms max. load) 2.0 mA - Calibration mode < 1.0 mA - Sensor malfunction
Calibration
Non-Intrusive activated by internal magnetic switch
Cable Requirement
3 wire shielded cable. Max loop resistance of 20 Ohms @ 24 VDC nominal
Cable Entry Hub
¾" NPT Female
Other Toxic Gas sensors available
Call factory or visit www.pem-tech.com
|