Download Datasheet
Ultra 1000 Toxic & Oxygen Sensor
Features
- RS-485 MODBUS Serial Output
- 4-20mA Analog Output
- 12-28 VDC Operation
- Automated Non-Intrusive Calibration
- Fully Adjustable Alarm Relay
- Lower wiring costs
Description
Ultra 1000 series is a microprocessor based addressable sensor for toxic gas detection. The self- contained sensor features user friendly interface and menu driven calibration procedure and configuration.
The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a transmitter board assembly. All of the sensor electronics are enclosed in an explosion proof instrument box. The unit’s modular design allows easy maintenance, troubleshooting and high reliability.
The unit provides a 4-20mA signal proportional to 0 to 100% of the detection range. In addition the sensor may be addressed via MODBUS RTU interface. The MODBUS output provides sensor status, alarm & fault conditions. Alarm levels can be programmed via MODBUS RTU or via magnetic switch on the face of the transmitter board assembly.
Ultra 1000 can be calibrated in less than 2 ½ minutes. The calibration and the set-up parameters are retained in a non-volatile memory.
Specifications
- Sensor Type
- Electrochemical
- Measuring Range
-
Ammonia (NH3) 50 ppm Carbon Monoxide (CO) 100 & 1000 ppm Chlorine (CL2) 10 ppm Chlorine Dioxide (CLO2) 50 ppm Ethylene (C2H4) 100 pm Ethylene Oxide (C2H4O) 50 ppm Hydrogen Chloride (HCL) 20 ppm Hydrogen Sulfide (H2S) 100 ppm Hydrogen (H2) 100 & 1000 ppm Hydrogen Cyanide (HCN) 30 ppm Methyl Mercaptan (CH3SH) 100 ppm Nitrogen Dioxide (NO2) 20 ppm Nitric Oxide (NO) 100 ppm Oxygen Deficiency (O2) 25% Sulfur Dioxide (SO2) 50 ppm
-
- Repeatability
- ± 2 % Full scale
- Zero Drift
- < 5% per year
- Response Time
- T90 < 30 seconds
- Classification
- Class I, division 1, Groups B,C & D
- Operating Temperature
- -4°F to +122°F (-20°C to +50°C)
- Operating Humidity
- 15% to 90% RH, non-condensing
- Display
- 2 lines by 8 Character LC Display with back light
- Mechanical Specifications
- Length: 7 inches (178 mm)
- Width: 5 inches (127 mm)
- Height: 4.5 inches (114 mm)
- Status Indicators
- Three-digit display for gas concentration, Alarm relay status, calibration mode and sensor fault status.
- Input Power
- 14-28 VDC. 24 VDC nominal
- Power Consumption
- 90mA @ 24 VDC Typical
- Alarm Relays
- Fully programmable.
- 0 to Full scale range of the sensor.
- Latching or Non-Latching.
- Relay Ratings
- SPDT Form “C” type Relay contacts
- 5 Amps @ 250 VAC or 30 VDC
- Analog Output
- Linear 4-20mA (300 Ohms max. load)
- 2.0 mA - Calibration mode
- < 1.0 mA - Sensor malfunction
- Calibration
- Non-Intrusive activated by internal magnetic switch
- Cable Requirement
- 3 wire shielded cable. Max loop resistance 20 Ohms
- Cable Entry Hub
- ¾” NPT Female


