Download Datasheet
PT395 Series Toxic & Oxygen Sensor
Features
- Microprocessor based modular design
- Electrochemical Sensor Technology
- Industry standard 4-20mA output
- Field adjustable Alarm level
- Single point Non-Intrusive calibration
- Bright 3 digit LED display
- Displays gas concentration in ppm, calibration prompts and sensor fault codes
- Suitable for use in Hazardous Location
Description
Model PT395 Series is a microprocessor-based sensor for the detection of toxic gas in ambient air. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas.
The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a transmitter board assembly. All of the sensor electronics are enclosed in an explosion proof instrument box. The unit’s modular design allows easy maintenance, troubleshooting and high reliability.
The unit provides a fully programmable alarm relay and a linear 4-20mA signal proportional to 0 to 100% of the detection range of the sensor.
The sensor transmitter board includes a three (3) digit LED display for continuous indication of the gas concentration. The calibration mode, alarm and fault status of the sensor are also indicated on the digital display. In the normal operating mode the digital display and 4-20mA reading is proportional to the gas concentration detected by the sensor. In the calibration mode the digital display indicates the calibration status, alarm relay output is inhibited and analog signal output is set to 2 mA to avoid any false alarm by the control monitor. In the sensor fault mode the transmitter drops the output signal to < 1 mA.
Specifications
- Sensor Type
- Electrochemical
- Measuring Ranges
-
Ammonia (NH3) 50 ppm Carbon Monoxide (CO) 100 & 1000 ppm Chlorine (CL2) 10 ppm Chlorine Dioxide (CLO2) 50 ppm Ethylene (C2H4) 100 pm Ethylene Oxide (C2H4O) 50 ppm Hydrogen Chloride (HCL) 20 ppm Hydrogen Sulfide (H2S) 100 ppm Hydrogen (H2) 100 & 1000 ppm Hydrogen Cyanide (HCN) 30 ppm Methyl Mercaptan (CH3SH) 100 ppm Nitrogen Dioxide (NO2) 20 ppm Nitric Oxide (NO) 100 ppm Oxygen Deficiency (O2) 25% Sulfur Dioxide (SO2) 50 ppm
-
- Repeatability
- ± 2 % Full scale
- Zero Drift
- < 5% per year
- Response Time
- T90 < 30 seconds with 100% FS gas applied
- Classification
- Class I, division 1, Groups B,C & D
- Operating Temperature
- -4°F to +122°F (-20°C to +50°C)
- Operating Humidity
- 15% to 90% RH, non-condensing
- Display
- Bright 3 digit LED display
- Approvals
- CSA / AT